SPEC*EDGE™2000 USER’S MANUAL Developed by: pogee Systems, Inc.An Employee-Owned Company TECHNICAL SUPPORT 2323 Cross Creek Dri
Spec*Edge Version 3.9 June 11, 2008 Analysis - i SPEC*EDGE™ ANALYSIS Section Page 1.0 Introduction ...
Spec*Edge Version 3.9 June 11, 2008 Analysis - 1 SPEC*EDGE™ ANALYSIS 1.0 Introduction: The Spec*Edge™ software was developed to support on-going
Spec*Edge Version 3.9 June 11, 2008 Analysis - 2 The analysis will be accomplished on each sheet in the order scanned as fast as the computer can do
Spec*Edge Version 3.9 June 11, 2008 Analysis - 3 NOTE: The Button located on the Setup screen must be checked to allow the operator to view the gra
Spec*Edge Version 3.9 June 11, 2008 Analysis - 4 3.2 Cut Quality: The cut quality measurement is the standard deviation of the cut quality edge dat
Spec*Edge Version 3.9 June 11, 2008 Analysis - 5 Figure 2d shows the selected zoom area defined as between 3.25 and 3.7 inches from the left side of
Spec*Edge Version 3.9 June 11, 2008 Analysis - 6 Figure 2e – Cut Quality Zoomed Image Figure 2f – Cut Quality Distribution 3.4 Sheet Cut Distrib
Spec*Edge Version 3.9 June 11, 2008 Analysis - 7 Figure 2g – Edge Image 3.5 Edge Image: The image presented to the operator to verify the existence
Spec*Edge Version 3.9 June 11, 2008 Analysis - 8 3.7 Hole Data: (Figure 4). Spec*Edge™ identifies the location and size of holes in punched paper.
Spec*Edge Version 3.9 June 11, 2008 Analysis - 9 Figure 5 - Hole Image 3.8 Hole Image: The center of the hole is marked by a white “X”. The diamet
Spec*Edge Version 3.9 June 11, 2008 Forward - i Forward This manual describes the installation and usage of the Spec*Edge™ paper quality control s
Spec*Edge Version 3.9 June 11, 2008 Analysis - 10 inches. This measurement is compared to the data in the specification. Spec*Edge™ will also provi
Spec*Edge Version 3.9 June 11, 2008 Analysis - 11 3.11 Summary Data: Once the measurement is complete the operator may click with the left mouse but
Spec*Edge Version 3.9 June 11, 2008 Analysis - 12 4.0 Print All Of The Results Of The Test: The operator may whish to see all of the results at one
Spec*Edge Version 3.9 June 11, 2008 Running - i RUNNING SPEC*EDGE™ Section Page 1 Introduction ...
Spec*Edge Version 3.9 June 11, 2008 Running - 1 RUNNING SPEC*EDGE™ 1. Introduction: The Spec*Edge™ software was developed to support on-going qu
Spec*Edge Version 3.9 June 11, 2008 Running - 2 Figure 1 - Windows 95 Start, Programs, Spec*Edge™ selection 2.2 Spec*Edge™ Operator Screen: When
Spec*Edge Version 3.9 June 11, 2008 Running - 3 Figure 2a – Information Panel Information Panel (Figure 2a): This panel displays information about
Spec*Edge Version 3.9 June 11, 2008 Running - 4 Figure 2b - Measurement OK/Warn/Fail Panel OK/Warn/Fail Panel (Figure 2b): This panel indicates eac
Spec*Edge Version 3.9 June 11, 2008 Running - 5 Figure 2c - Pockets (Sheets) Indicator Panel Pockets (Sheets) Indicator Panel (Figure 2c): This pa
Spec*Edge Version 3.9 June 11, 2008 Running - 6 Indicates that the pocket (sheet) is complete. The indicator reflects the worst condition detected
Spec*Edge Version 3.9 June 11, 2008 Forward - ii please call the Apogee support line at the number on the front cover of the User's Manual.
Spec*Edge Version 3.9 June 11, 2008 Running - 7 Cancel Scan/Delete – Allows you to cancel or delete the scan. The Cancel button will appear in pl
Spec*Edge Version 3.9 June 11, 2008 Running - 8 4. Running a Typical Spec*Edge™ Test: Step 1: Place the sample to be tested on the scanner glass a
Spec*Edge Version 3.9 June 11, 2008 Running - 9 (Single Edge) (Full Sheet) Figure 4 – Sample Analyzed 5. Viewing Results: NOTE: The But
Spec*Edge Version 3.9 June 11, 2008 Running - 10 Figure 5 – Summary Screen Step 2: Click the left mouse button on the <Print> button (FIGURE
Spec*Edge Version 3.9 June 11, 2008 Setup - i SPEC*EDGE™ SETUP Section Page 1 Introduction ...
Spec*Edge Version 3.9 June 11, 2008 Setup - 1 SPEC*EDGE™ SETUP 1. Introduction Spec*Edge™ was developed to support on-going quality control mea
Spec*Edge Version 3.9 June 11, 2008 Setup - 2 NOTE: Once an organization has established their settings in Spec*Edge™ it is recommended that the in
Spec*Edge Version 3.9 June 11, 2008 Setup - 3 Figure 2b – Password Change Screen Step 3: The operator then enters a desired password two (2) tim
Spec*Edge Version 3.9 June 11, 2008 Setup - 4 2.2.1 Add, Delete or Change An Operator: The Operator area identifies the names of valid operators.
Spec*Edge Version 3.9 June 11, 2008 Setup - 5 from the list or click on the sheet name in the edit window to alter the test name Step 2: Click on
Spec*Edge Version 3.9 June 11, 2008 Installation. i SPEC*EDGE™ INSTALLATION Section Page 1. Introduction ...
Spec*Edge Version 3.9 June 11, 2008 Setup - 6 When this field is non-zero (1 - 11), the hole specification (diameter of all holes, and for each hole
Spec*Edge Version 3.9 June 11, 2008 Setup - 7 2.2.8 Setting The Database Path: The Database Path serves the purpose of setting the file path for
Spec*Edge Version 3.9 June 11, 2008 Setup - 8 2.2.9 Setting The Graphic Output Screen Status: The Graphic Output Screen Status feature enables th
Spec*Edge Version 3.9 June 11, 2008 Setup - 9 2.2.12 Setting the Setup Path: Figure 4b – Setup File Path The Setup Path feature of Spec*Edge gi
Spec*Edge Version 3.9 June 11, 2008 Setup - 10 2.2 Calibration: Spec*Edge uses UMAX scanners with high resolution 800 x 800 or 700 x 700 dpi o
Spec*Edge Version 3.9 June 11, 2008 Setup - 11 Any operator may view the setup screen by typing in any name in the password, however, the entry fie
Spec*Edge Version 3.9 June 11, 2008 Setup - 12 SOFTWARE DEFICIENCY REPORT DATE: NAME: COMPANY NAME: COMPANY ADDRESS: PHONE NUMBER: FAX NUMBER:
Spec*Edge Version 3.9 June 11, 2008 Setup - 13 DESCRIPTION OF PROBLEM (Please describe the problem, what buttons you clicked, etc. in as much deta
Spec*Edge Version 3.9 June 11, 2008 Installation - 1 SPEC*EDGE™ INSTALLATION 1. Introduction: Spec*Edge™ was developed for the paper industry to
Spec*Edge Version 3.9 June 11, 2008 Installation - 2 NOTE: To keep your old settings, copy the file <specedge setup.ses> located in the <Apo
Spec*Edge Version 3.9 June 11, 2008 Installation - 3 load and display the following screen which is where you must select which scanner your are goin
Spec*Edge Version 3.9 June 11, 2008 Installation - 4 port, cannot work through the plug. In this case, put the plug between the tape drive and the p
Spec*Edge Version 3.9 June 11, 2008 Installation - 5 4. Setting Spec*Edge™ to Start Automatically: The installation process placed the Spec*Edge™